The SunSynk 10KW 48V Single Phase Hybrid Inverter is a highly efficient power management tool that allows the user to hit those ‘parity’ targets by managing power-flow from multiple sources such as solar, mains power (grid) and generators, and then effectively storing and releasing power as and when utilities require.
Applications
Marine (vessel power management).
Power shedding (home/office/factory).
UPS (fuel-saving systems).
Remote locations with solar and wind generators.
Building sites.
Telecommunication.
Technical Specifications Battery Input Data
Battery Type: Lead-acid or Lithium-ion.
Battery Voltage Range: 40~60V.
Max. Charging Current: 220A.
Max. Discharging Current: 220A.
Charging Curve: 3 Stages/Equalization.
Charging Strategy for Li-Ion: Battery Self-adaption to BMS.
PV String Input Data
Max. DC Input Power: 13000W.
PV Input Voltage: 370V (125V~500)
Start-up Voltage: 125V
MPPT Range: 150V~425V.
Full Load Dc Voltage Range: 200V-425V
PV Input Current: 26A+26A+26A+
Max. PV Isc:44A+44A+44A
No. of Strings Per MPPT Tracker: 3 / 2+2+2
AC Output Data
Rated AC Output and UPS Power: 10000W.
Max. AC Power: 11000W.
AC Output Rated Current: 45.5/43.5A
Max AC Output Current: 50/47.9A
Max Continuous AC Passthrough: 70A.
Peak Power (Off Grid): 2 Time of Rated Power, 10 S
Power Factor Adjustment Range:0.8 Leading to 0.8 Lagging
Power Factor: 1
Output Frequency and Voltage: 50 / 60Hz; L/N/PE 220/230Vac
Grid Type: Split Phase; 2/3 phase, Single Phase
Total Harmonics Current Distortion (THDi):<3% (of nominal power)
Current Harmonic Distortion: THD<3% (Linear load<1.5%).
DC Current Injection:<0.5% In
Efficiency
Max. Efficiency: 97.6%.
MPPT Efficiency: 97.0%.
Euro Efficiency: 99.9%.
Protection
Integrated: Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current
Protection, Output Shorted Protection, Surge Protection
Over Voltage Category: DC Type II/AC Type III
Certifications and Standards:
Grid Regulation: VDE4105, IEC61727/62116, VDE0126, AS4777.2, CEI 0 21, EN50549-1, G98, G99, C10-11, UNE217002, NBR16149/NBR16150
Safety EMC / Standard: IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
General Data
Operating Temperature Range -40~60°C, >45°C Derating.
Cooling: Smart Cooling
Noise: ≤30 dB
Communication with BMS RS485; CAN.
Weight: 32kg.
Size: 420W×670H×233D mm (Excluding connectors and brackets)
Protection Degree: IP65.
Installation Style: Wall-mounted.
Warranty: 5 years.